Project Address Created Type Crew Age (days) ↓ Comments
VERO_N_SEGMENT3_CON 36.10991, -96.77832 2026-07-15 Restoration_Other Unassigned 54 Rocks per DOT need to be removed so that they can mow grass/ no change as of 08/17
VERO_N_SEGMENT2_CON 36.11533, -96.80992 2026-07-23 Restoration_Softscape Unassigned 46 Rocks need to be removed from job site
VERO_S_SEGMENT3_CON 35.99636, -96.60826 2026-07-24 Restoration_Other Unassigned 45 Hydro vac hole needs to be backfilled.
VERO_N_SEGMENT3_CON 36.11524, -96.81095 2026-07-30 Restoration_Softscape Unassigned 39 Rocks and trash need to be removed from site
VERO_N_SEGMENT3_CON 36.11492, -96.80304 2026-07-30 Restoration_Softscape Unassigned 39 Rock pile needs to be removed
VERO_S_SEGMENT3_CON 36.11553, -97.06258 2026-08-17 Restoration_Softscape Unassigned 21 Vault needs to be re-leveled and surrounding ground sinkage needs to be filled in
VERO_N_SEGMENT5_CON 36.12628, -96.38917 2026-08-18 Conduit_Entry Unassigned 20 conduit cannot cross, each package must be on their designated sides
VERO_S_SEGMENT3_CON 36.11553, -97.06261 2026-08-20 Locate_Other Unassigned 18 missing marker post
VERO_N_SEGMENT3_CON 36.11451, -96.79910 2026-08-24 Conduit_Entry Unassigned 14 conduit cannot cross, must be on designated sides of the vault
VERO_S_SEGMENT3_CON 35.98528, -97.05100 2026-08-25 Structure_Grounding Unassigned 13 wire or tracer wire inside marker post.
VERO_N_SEGMENT2_CON 36.11639, -96.89870 2026-08-26 Markerpost Unassigned 12 Missing marker / grounding post
VERO_N_SEGMENT2_CON 36.11618, -96.89004 2026-08-26 Markerpost Unassigned 12 Missing marker post cap.
VERO_N_SEGMENT2_CON 36.11601, -96.86683 2026-08-26 Markerpost Unassigned 12 Terminals need to be cut to fit marker post
VERO_N_SEGMENT4_CON 36.11907, -96.57615 2026-08-26 Markerpost Unassigned 12 Marker Post - Connect both tracer and ground with a jumper. Missing HH label and black band.
VERO_N_SEGMENT3_CON 36.11529, -96.80691 2026-08-26 Pole_Grounding Unassigned 12 Jumper wire needs to be connected to ground and tracer inside marker post. All tracer wire must be visible inside of the vault. Remove mule tape from vault lid.
VERO_N_SEGMENT4_CON 36.11716, -96.62613 2026-08-26 Structure_Other Unassigned 12 Missing all photos.
VERO_N_SEGMENT3_CON 36.11253, -96.79168 2026-08-26 Markerpost Unassigned 12 (might want to wait until fiber has been fully installed to clear these) HH label not legible in photo, Clean up rocks surrounding vault. Conduit needs capped (possibly take after fiber has been installed). Remove mule tape from vault lid.
VERO_N_SEGMENT2_CON 36.11577, -96.84968 2026-08-26 Markerpost Unassigned 12 Post - Connect all tracer and ground with jumper, clear photo of HH label, all tracer wire must be visible inside vault
VERO_N_SEGMENT5_CON 36.13063, -96.37378 2026-08-26 Restoration_Other Unassigned 12 Cond. it cannot cross. Pull back conduit to both sides of the vault, trim extra length afterwards. Softscape restoration needed around vault to bring vault to grade. Inside vault photo needs Vero sticker.
VERO_S_SEGMENT3_CON 35.98569, -96.85753 2026-08-26 Structure_Other Unassigned 12 Connect tracer wire and ground with jumper wire inside marker post. Backfill dirt around vault to bring vault to grade.
VERO_S_SEGMENT3_CON 35.98569, -96.85753 2026-08-26 Markerpost Unassigned 12 Connect tracer wire and ground with jumper wire inside marker post. Backfill dirt around vault to bring vault to grade.
VERO_S_SEGMENT3_CON 35.98496, -96.76892 2026-08-26 Pole_Grounding Unassigned 12 No photo of inside marker post, make sure tracer and ground has a jumper together. Conduit not capped. Unable to see ground rod.
VERO_S_SEGMENT3_CON 35.98498, -96.71304 2026-08-26 Restoration_Other Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape. Missing photo of interior vault and vero sticker.
VERO_S_SEGMENT3_CON 35.98498, -96.71304 2026-08-26 Markerpost Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape. Missing photo of interior vault and vero sticker.
VERO_S_SEGMENT3_CON 35.98530, -97.04887 2026-08-26 Pole_Grounding Unassigned 12 Marker post needs jumper between ground and tracers. Missing seal on conduit
VERO_S_SEGMENT3_CON 35.98557, -96.83241 2026-08-26 Structure_Other Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Unbury tracer wire inside vault. Trim three-way conduit. Conduit obscured by fiber (can't see sealant)
VERO_S_SEGMENT3_CON 35.98557, -96.83241 2026-08-26 Markerpost Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Unbury tracer wire inside vault. Trim three-way conduit. Conduit obscured by fiber (can't see sealant)
VERO_N_SEGMENT2_CON 36.11596, -96.99959 2026-08-27 Structure_Other Unassigned 12 Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Cannot see ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible.
VERO_N_SEGMENT2_CON 36.11596, -96.99959 2026-08-27 Markerpost Unassigned 12 Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Cannot see ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible.
VERO_N_SEGMENT2_CON 36.11598, -97.00806 2026-08-27 Structure_Other Unassigned 12 Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Ground rod not visible. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT2_CON 36.11598, -97.00806 2026-08-27 Restoration_Other Unassigned 12 Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Ground rod not visible. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT2_CON 36.11598, -97.00806 2026-08-27 Markerpost Unassigned 12 Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Ground rod not visible. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT5_CON 36.13078, -96.37378 2026-08-26 Restoration_Other Unassigned 12 Vault is washing out
VERO_N_SEGMENT2_CON 36.11614, -96.98919 2026-08-27 Markerpost Unassigned 12 Take photos from further back to see full restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible.
VERO_N_SEGMENT5_CON 36.12849, -96.32774 2026-08-26 Structure_Other Unassigned 12 Smooth terrain around vault. One duct pack not visible. Duct pact must not be crossing, pull ducts back to both sides of the vault for separation, trim to proper length if necessary. Missing ground wire and jumper inside marker post. Missing vero label inside vault. Missing HH label and vero sticker on marker post.
VERO_N_SEGMENT2_CON 36.11636, -96.94323 2026-08-27 Restoration_Other Unassigned 12 Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible.
VERO_N_SEGMENT2_CON 36.11636, -96.94323 2026-08-27 Markerpost Unassigned 12 Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible.
VERO_S_SEGMENT3_CON 35.98507, -96.72132 2026-08-27 Restoration_Other Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Sealant missing on conduit. Not all conduit visible
VERO_S_SEGMENT3_CON 35.98507, -96.72132 2026-08-27 Markerpost Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Sealant missing on conduit. Not all conduit visible
VERO_N_SEGMENT7_CON 36.13341, -96.05900 2026-08-26 Structure_Other Unassigned 12 Missing all photos.
VERO_N_SEGMENT2_CON 36.11543, -96.82472 2026-08-26 Markerpost Unassigned 12 Connect tracer wire and ground with jumper. Tracer wire must be visible inside vault (not buried). Unable to read HH number on marker post.
VERO_N_SEGMENT5_CON 36.11571, -96.40886 2026-08-26 Structure_Other Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Apply dirt around vault to bring to grade and restore surrounding softscape. Unbury tracer wire inside vault. Vero sticker not visible on inside vault photo.
VERO_N_SEGMENT5_CON 36.11571, -96.40886 2026-08-26 Markerpost Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Apply dirt around vault to bring to grade and restore surrounding softscape. Unbury tracer wire inside vault. Vero sticker not visible on inside vault photo.
VERO_N_SEGMENT3_CON 36.11672, -96.66077 2026-08-26 Structure_Other Unassigned 12 Remove excess rocks behind vault. Missing photo of marker post wiring, hand hole label not legible. Need a closer and clearer photo of the inside vault
VERO_N_SEGMENT2_CON 36.11637, -96.92638 2026-08-27 Markerpost Unassigned 12 Take photos from further back to see full restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Ground rod not visible
VERO_N_SEGMENT5_CON 36.11921, -96.40208 2026-08-26 Pole_Grounding Unassigned 12 Marker post needs jumper wire connecting tracer wires to ground.
VERO_S_SEGMENT3_CON 35.98504, -96.69637 2026-08-26 Markerpost Unassigned 12 Connect tracer wires and ground wire with jumper in marker post.
VERO_N_SEGMENT3_CON 36.11451, -96.79911 2026-08-26 Markerpost Unassigned 12 Connect jumper between tracer and ground wire in post. Cannot see all of the conduit, obscured by lid. Tracer wire must be visible in vault and not buried
VERO_N_SEGMENT2_CON 36.11633, -96.93485 2026-08-27 Restoration_Other Unassigned 12 Take photos from further back to see full restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT2_CON 36.11633, -96.93485 2026-08-27 Markerpost Unassigned 12 Take photos from further back to see full restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT2_CON 36.11609, -96.87317 2026-08-26 Structure_Other Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Unbury conduit from gravel. Backfill dirt around vault to bring to grade.
VERO_N_SEGMENT2_CON 36.11609, -96.87317 2026-08-26 Markerpost Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Unbury conduit from gravel. Backfill dirt around vault to bring to grade. Hand Hole label not legible
VERO_N_SEGMENT5_CON 36.12629, -96.38917 2026-08-26 Structure_Other Unassigned 12 Conduit cannot be crossed. Pull back conduit to either side of vault, trim to proper length. Clean dirt from top of vault for pictures. Photo of HH label is too blurry. Jumper wire needs to be connected to tracer and ground. Inside vault picture must show the Vero sticker
VERO_N_SEGMENT1_CON 36.11595, -97.02485 2026-08-27 Restoration_Other Unassigned 12 Take photos from further back to see full restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Ground rod not visible, drain vault. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT1_CON 36.11595, -97.02485 2026-08-27 Markerpost Unassigned 12 Take photos from further back to see full restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Ground rod not visible, drain vault. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT2_CON 36.11615, -96.88124 2026-08-27 Restoration_Other Unassigned 12 Take photos from further back to show restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Conduit not fully visible. Tracer wire not fully visible.
VERO_N_SEGMENT2_CON 36.11615, -96.88124 2026-08-27 Markerpost Unassigned 12 Take photos from further back to show restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Conduit not fully visible. Tracer wire not fully visible.
VERO_N_SEGMENT2_CON 36.11601, -97.01519 2026-08-27 Restoration_Other Unassigned 12 Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Ground rod not visible. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible.
VERO_N_SEGMENT2_CON 36.11601, -97.01519 2026-08-27 Markerpost Unassigned 12 Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Ground rod not visible. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible.
VERO_N_SEGMENT5_CON 36.13041, -96.38140 2026-08-26 Pole_Grounding Unassigned 12 Conduit cannot be crossed, pull back conduit to both sides of the vault, trim to length afterwards. Connect jumper wire between tracer and ground wire in marker post, remove rocks from surrounding softscape, ground rod must be driven further into the ground. Vero sticker not visible inside vault.
VERO_S_SEGMENT3_CON 35.98579, -96.86603 2026-08-26 Markerpost Unassigned 12 Install jumper wire to tracer wire and ground wire in marker post
VERO_S_SEGMENT3_CON 35.98526, -96.70466 2026-08-26 Restoration_Other Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Unbury tracer wire inside vault. Three-way conduit not visible. Ground rod not visible. Remove rocks from around vault.
VERO_S_SEGMENT3_CON 35.98526, -96.70466 2026-08-26 Markerpost Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Unbury tracer wire inside vault. Three-way conduit not visible. Ground rod not visible. Remove rocks from around vault.
VERO_S_SEGMENT3_CON 35.98530, -96.72936 2026-08-27 Restoration_Other Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_S_SEGMENT3_CON 35.98530, -96.72936 2026-08-27 Markerpost Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT3_CON 36.11537, -96.81565 2026-08-26 Restoration_Other Unassigned 12 Fill in and compact all sunken softscape around vault and plow lines visible from photos. Drain water and take updated interior vault photo. Connect tracer and ground wire with jumper
VERO_S_SEGMENT3_CON 35.98562, -96.80752 2026-08-26 Structure_Other Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Unbury tracer wire inside vault. install additional dirt around vault to bring to grade.
VERO_S_SEGMENT3_CON 35.98562, -96.80752 2026-08-26 Markerpost Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Unbury tracer wire inside vault. install additional dirt around vault to bring to grade.
VERO_N_SEGMENT5_CON 36.12287, -96.39533 2026-08-26 Restoration_Other Unassigned 12 Inside vault photo must include vero sticker. Install jumper wire between tracer wire and ground inside marker post.
VERO_S_SEGMENT3_CON 35.98518, -96.77406 2026-08-26 Markerpost Unassigned 12 connect tracer and ground wires with jumper in marker post.
VERO_N_SEGMENT2_CON 36.11632, -96.95732 2026-08-27 Restoration_Other Unassigned 12 Take photos from further back to see full restoration. Ground rod not visible. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT2_CON 36.11632, -96.95732 2026-08-27 Markerpost Unassigned 12 Take photos from further back to see full restoration. Ground rod not visible. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT2_CON 36.11620, -96.97423 2026-08-27 Structure_Other Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Three-way conduit not visible
VERO_N_SEGMENT2_CON 36.11620, -96.97423 2026-08-27 Markerpost Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Three-way conduit not visible
VERO_S_SEGMENT3_CON 35.98579, -96.88243 2026-08-26 Markerpost Unassigned 12 Connect tracer and ground with jumper in marker post.
VERO_N_SEGMENT2_CON 36.11589, -96.85873 2026-08-26 Restoration_Other Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT2_CON 36.11589, -96.85873 2026-08-26 Markerpost Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT2_CON 36.11630, -96.96577 2026-08-27 Markerpost Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible.
VERO_S_SEGMENT3_CON 35.98548, -96.78200 2026-08-26 Markerpost Unassigned 12 Connect tracer and ground with jumper in marker post.
VERO_S_SEGMENT3_CON 35.98554, -96.87404 2026-08-26 Restoration_Other Unassigned 12 Backfill dirt around vault to bring vault to grade. Conduit missing plugs. Connect tracer wire and ground wire with jumper in marker post.
VERO_S_SEGMENT3_CON 35.98554, -96.87404 2026-08-26 Markerpost Unassigned 12 Backfill dirt around vault to bring vault to grade. Conduit missing plugs. Connect tracer wire and ground wire with jumper in marker post.
VERO_N_SEGMENT2_CON 36.11652, -96.91083 2026-08-27 Restoration_Other Unassigned 12 Take photos further back to show full restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT2_CON 36.11652, -96.91083 2026-08-27 Markerpost Unassigned 12 Take photos further back to show full restoration. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_S_SEGMENT3_CON 35.98553, -96.79079 2026-08-26 Restoration_Other Unassigned 12 Backfill softscape around the vault to bring to grade, connect tracer wire and ground wire with jumper in marker post, sealant needed on conduit with fiber.
VERO_S_SEGMENT3_CON 35.98553, -96.79079 2026-08-26 Markerpost Unassigned 12 Backfill softscape around the vault to bring to grade, connect tracer wire and ground wire with jumper in marker post, sealant needed on conduit with fiber.
VERO_S_SEGMENT3_CON 35.98568, -96.86806 2026-08-26 Restoration_Other Unassigned 12 backfill dirt around vault to bring vault to grade. Connect tracer and ground wire with jumper in marker post.
VERO_S_SEGMENT3_CON 35.98568, -96.86806 2026-08-26 Markerpost Unassigned 12 backfill dirt around vault to bring vault to grade. Connect tracer and ground wire with jumper in marker post.
VERO_S_SEGMENT3_CON 35.98532, -96.81593 2026-08-26 Restoration_Other Unassigned 12 Missing photo of marker post wiring and label. Apply more dirt around vault to bring to grade, fill in sinking softscape.
VERO_S_SEGMENT3_CON 35.98532, -96.81593 2026-08-26 Markerpost Unassigned 12 Missing photo of marker post wiring and label. Apply more dirt around vault to bring to grade, fill in sinking softscape.
VERO_S_SEGMENT3_CON 35.98561, -96.84899 2026-08-26 Structure_Other Unassigned 12 Connect tracer and ground with jumper in marker post. Drain vault and take photo of interior (ensure tracer visibility, ground rod installation, and conduit are sealed)
VERO_S_SEGMENT3_CON 35.98561, -96.84899 2026-08-26 Markerpost Unassigned 12 Connect tracer and ground with jumper in marker post. Drain vault and take photo of interior (ensure tracer visibility, ground rod installation, and conduit are sealed)
VERO_S_SEGMENT3_CON 35.98553, -96.79918 2026-08-26 Structure_Other Unassigned 12 Connect tracer wires and ground wire with a jumper inside marker post. Backfill dirt around vault to bring vault to grade. Conduit around fiber needs sealant.
VERO_S_SEGMENT3_CON 35.98553, -96.79918 2026-08-26 Markerpost Unassigned 12 Connect tracer wires and ground wire with a jumper inside marker post. Backfill dirt around vault to bring vault to grade. Conduit around fiber needs sealant.
VERO_S_SEGMENT3_CON 35.98560, -96.84083 2026-08-26 Restoration_Other Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Apply dirt around vault to bring to grade and restore surrounding softscape. Unbury tracer wire inside vault.
VERO_S_SEGMENT3_CON 35.98560, -96.84083 2026-08-26 Markerpost Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Apply dirt around vault to bring to grade and restore surrounding softscape. Unbury tracer wire inside vault.
VERO_N_SEGMENT2_CON 36.11558, -96.84156 2026-08-26 Restoration_Other Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT2_CON 36.11558, -96.84156 2026-08-26 Markerpost Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT2_CON 36.11620, -96.98326 2026-08-27 Structure_Other Unassigned 12 Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible.
VERO_N_SEGMENT2_CON 36.11620, -96.98326 2026-08-27 Markerpost Unassigned 12 Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible.
VERO_N_SEGMENT2_CON 36.11550, -96.83337 2026-08-26 Restoration_Other Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault and restore surrounding softscape and holes.
VERO_N_SEGMENT2_CON 36.11550, -96.83337 2026-08-26 Markerpost Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault and restore surrounding softscape and holes.
VERO_N_SEGMENT2_CON 36.11602, -96.86829 2026-08-26 Markerpost Unassigned 12 Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible.
VERO_N_SEGMENT2_CON 36.11643, -96.90683 2026-08-27 Markerpost Unassigned 12 Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_S_SEGMENT3_CON 35.98521, -96.68780 2026-08-26 Markerpost Unassigned 12 Connect tracer wires and ground wire with jumper in marker post.
VERO_S_SEGMENT3_CON 35.98531, -96.67979 2026-08-26 Restoration_Other Unassigned 12 Fill in dirt around vault to bring to grade.
VERO_N_SEGMENT2_CON 36.11642, -96.91792 2026-08-27 Restoration_Other Unassigned 12 Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT2_CON 36.11642, -96.91792 2026-08-27 Markerpost Unassigned 12 Take photos from further back to see full restoration. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not visible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT2_CON 36.11629, -96.94799 2026-08-27 Structure_Other Unassigned 12 Take photos from further back to see full restoration. Vault damaged, vault replacement may be necessary. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT2_CON 36.11629, -96.94799 2026-08-27 Restoration_Other Unassigned 12 Take photos from further back to see full restoration. Vault damaged, vault replacement may be necessary. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_N_SEGMENT2_CON 36.11629, -96.94799 2026-08-27 Markerpost Unassigned 12 Take photos from further back to see full restoration. Vault damaged, vault replacement may be necessary. Missing ground wire inside marker post, install missing ground wire. Tracer wire cannot connect directly to ground rod. Connect tracer wires and ground wire with jumper in marker post. Hand hole label not legible. Apply dirt around vault to bring to grade and restore surrounding softscape.
VERO_S_SEGMENT3_CON 35.98506, -96.65449 2026-08-27 Conduit_Sealed Unassigned 12 Ground rod not visible, conduit not sealed around fiber.
VERO_N_SEGMENT3_CON 36.11132, -96.78441 2026-08-27 Structure_Other Unassigned 12 Need photos post fiber installation. Hand hole label not legible. Conduit not sealed around fiber. Ground wire not connected to ground rod. Remove mule tape from vault lid.
VERO_N_SEGMENT3_CON 36.11132, -96.78441 2026-08-27 Conduit_Sealed Unassigned 12 Need photos post fiber installation. Hand hole label not legible. Conduit not sealed around fiber. Ground wire not connected to ground rod. Remove mule tape from vault lid.
VERO_N_SEGMENT3_CON 36.11132, -96.78441 2026-08-27 Markerpost Unassigned 12 Need photos post fiber installation. Hand hole label not legible. Conduit not sealed around fiber. Ground wire not connected to ground rod. Remove mule tape from vault lid.
VERO_N_SEGMENT3_CON 36.10915, -96.77561 2026-08-27 Structure_Other Unassigned 12 Conduit too long. Conduit not sealed. Backfill needed around vault. Hand hole label not legible.
VERO_N_SEGMENT3_CON 36.10915, -96.77561 2026-08-27 Conduit_Sealed Unassigned 12 Conduit too long. Conduit not sealed. Backfill needed around vault. Hand hole label not legible.
VERO_N_SEGMENT3_CON 36.10915, -96.77561 2026-08-27 Markerpost Unassigned 12 Conduit too long. Conduit not sealed. Backfill needed around vault. Hand hole label not legible.
VERO_S_SEGMENT3_CON 35.98525, -96.67126 2026-08-27 Conduit_Sealed Unassigned 12 Three-way conduit buried. Backfill and restore softscape around vault.
VERO_S_SEGMENT3_CON 35.98525, -96.67126 2026-08-27 Restoration_Other Unassigned 12 Three-way conduit buried. Backfill and restore softscape around vault.
VERO_N_SEGMENT3_CON 36.10830, -96.76646 2026-08-27 Conduit_Sealed Unassigned 12 Hand hole label not legible. Tracer not visible inside vault. Backfill and restore softscape around vault.
VERO_N_SEGMENT3_CON 36.10830, -96.76646 2026-08-27 Markerpost Unassigned 12 Hand hole label not legible. Tracer not visible inside vault. Backfill and restore softscape around vault.
VERO_S_SEGMENT3_CON 35.98538, -96.63786 2026-08-27 Structure_Grounding Unassigned 12 Remove trash from vault. Backfill and restore softscape around vault. Ground rod not properly installed.
VERO_S_SEGMENT3_CON 35.98540, -96.64617 2026-08-27 Structure_Grounding Unassigned 12 Backfill dirt around vault. Tracer wire inside vault not visible
VERO_S_SEGMENT3_CON 35.98540, -96.64617 2026-08-27 Restoration_Other Unassigned 12 Backfill dirt around vault. Tracer wire inside vault not visible
VERO_S_SEGMENT3_CON 35.98493, -96.66289 2026-08-27 Trash_Scraps Unassigned 12 Remove trash from inside vault. Backfill and restore softscape around vault.
VERO_N_SEGMENT5_CON 36.11718, -96.62614 2026-08-27 Markerpost Unassigned 11
VERO_N_SEGMENT5_CON 36.11937, -96.55024 2026-08-27 Other Unassigned 11 Mud in vault
VERO_N_SEGMENT6_CON 36.12157, -96.12377 2026-08-28 Conduit_Sealed Unassigned 10 Crews are out of the caps. They are not able to get any from the warehouse because we are out.
VERO_N_SEGMENT6_CON 36.13354, -96.21831 2026-09-01 Conduit_Length Unassigned 6 Conduits are too long, must be trimmed down to length. Drain water from vault. Backfill dirt around vault to bring to grade. Ensure all tracer wire is visible
VERO_N_SEGMENT3_CON 36.11645, -96.68635 2026-09-01 Markerpost Unassigned 6 HH label not legible, jumper wire needs to connect between tracer and ground. Restoration needed around vault
VERO_N_SEGMENT3_CON 36.11652, -96.67843 2026-09-01 Markerpost Unassigned 6 marker post wiring needs jumper between both tracer wire and ground post.
VERO_N_SEGMENT4_CON 36.11913, -96.60959 2026-09-01 Restoration_Other Unassigned 6 softscape restoration needed around vault to bring to grade. jumper wire not connected to ground wire lug.
VERO_N_SEGMENT5_CON 36.12952, -96.30071 2026-09-01 Structure_Other Unassigned 6 Unable to identify all conduit, tracer, and ground rod inside vault. Backfill dirt around vault to bring to grade.
VERO_N_SEGMENT6_CON 36.13351, -96.22677 2026-09-01 Conduit_Length Unassigned 6 Conduits cannot be crossing, pull back to each side of vault. Conduits too long, trim to proper lengths. Ground rod installed incorrectly.
VERO_N_SEGMENT6_CON 36.13230, -96.25208 2026-09-01 Conduit_Length Unassigned 6 Conduit ends too close together, separate conduit for more spacing. Ground rod needs to be driven further into the ground.
VERO_N_SEGMENT6_CON 36.13135, -96.26069 2026-09-01 Markerpost Unassigned 6 tracer wire should not be fully stripped to the copper inside marker post
VERO_S_SEGMENT3_CON 36.08127, -97.05154 2026-09-01 Conduit_Sealed Unassigned 6 Conduit not sealed around fiber. Tape falling off other conduits.
VERO_N_SEGMENT4_CON 36.11909, -96.61801 2026-09-01 Restoration_Other Unassigned 6 backfill around vault to bring to grade. jumper wire not connected to ground wire lug.
VERO_N_SEGMENT7_CON 36.12045, -96.11723 2026-09-01 Restoration_Other Unassigned 6 Restoration photos must be taken further back showing full length of softscape, not just a top-down view. Ground wire must be connected to copper lug on marker post.
VERO_N_SEGMENT6_CON 36.13806, -96.19339 2026-09-01 Restoration_Other Unassigned 6 post-restoration photos must be taken from further back to show full length of softscape around vault. Marker post cap needs vero sticker, not black banding. All tracer wire must be visible inside vault
VERO_N_SEGMENT4_CON 36.11739, -96.51329 2026-09-01 Markerpost Unassigned 6 Marker post wiring photo cut off, need a full picture of the wiring.
VERO_N_SEGMENT6_CON 36.13398, -96.20987 2026-09-01 Structure_Other Unassigned 6 Cannot see inside vault clearly enough, need water drained and new interior photo taken.
VERO_N_SEGMENT6_CON 36.12175, -96.12504 2026-09-01 Conduit_Sealed Unassigned 6 No micro duct caps were available to be put on.
VERO_S_SEGMENT3_CON 36.06745, -97.05156 2026-09-01 Restoration_Other Unassigned 6 Restoration needed around vault
VERO_N_SEGMENT5_CON 36.12905, -96.32032 2026-09-01 Structure_Grounding Unassigned 6 Ground rod installed incorrectly, needs to be driven further into the ground. All tracer wire must be visible inside vault. Marker post needs vero sticker, not black banding.
VERO_N_SEGMENT5_CON 36.12844, -96.36249 2026-09-01 Structure_Other Unassigned 6 Vero sticker is not present inside vault picture
VERO_N_SEGMENT4_CON 36.11908, -96.60078 2026-09-01 Restoration_Other Unassigned 6 softscape restoration needed around vault to bring to grade. Jumper wire not connected to ground wire lug.
VERO_N_SEGMENT5_CON 36.12710, -96.33886 2026-09-01 Structure_Grounding Unassigned 6 pull duct back to either sdie of the vault, trim conduit to length afterwards.Ground rod must be driven further into the ground.
VERO_S_SEGMENT3_CON 35.99905, -97.05105 2026-09-01 Restoration_Other Unassigned 6 massive sinking around vault, vault may need to be raised. Fill in sinking softscape around vault to bring to grade.
VERO_N_SEGMENT3_CON 36.11661, -96.66942 2026-09-01 Markerpost Unassigned 6 tracer and ground wire must have jumper installed connecting all three wires.
VERO_N_SEGMENT3_CON 36.11642, -96.66076 2026-09-01 Restoration_Other Unassigned 6 softscape restoration around vault needed
VERO_S_SEGMENT3_CON 36.09505, -97.05161 2026-09-01 Restoration_Other Unassigned 6 Restoration needed around vault. Conduit needs sealant around fiber cables. Remove trash from inside vault
VERO_N_SEGMENT4_CON 36.11639, -96.64279 2026-09-01 Markerpost Unassigned 6 Interior vault photo and marker post photo not from this vault. jumper wire must connect between tracer and ground wire lugs. Ground rod missing.
VERO_N_SEGMENT4_CON 36.12020, -96.51937 2026-09-01 Restoration_Other Unassigned 6 softscape restoration around vault to bring to grade. Interior photos are too blurry, retake photos.
VERO_N_SEGMENT3_CON 36.11641, -96.65213 2026-09-01 Restoration_Other Unassigned 6 softscape restoration around vault needed. Marker post jumper wire must be connected to ground and tracer
VERO_N_SEGMENT5_CON 36.12656, -96.34556 2026-09-01 Restoration_Other Unassigned 6 Conduit cannot be crossed, pull conduit back to both sides of the vault and trim to length. softscape restoration needed in front of vault
VERO_N_SEGMENT3_CON 36.11622, -96.69420 2026-09-01 Markerpost Unassigned 6 Jumper wire needs to be connected between tracers and ground lugs.
VERO_S_SEGMENT3_CON 36.08812, -97.05141 2026-09-01 Conduit_Sealed Unassigned 6 conduit not sealed between fiber
VERO_S_SEGMENT3_CON 36.10186, -97.05153 2026-09-01 Markerpost Unassigned 6 Missing both tracer wires inside marker post. Conduit not sealed, cannot see ground wire. remove trash from vault
VERO_N_SEGMENT6_CON 36.12542, -96.13674 2026-09-01 Restoration_Other Unassigned 6 Cannot identify vault in exterior photos. Remove dirt from vault lid and take new photos of exterior. Conduits cannot be crossed, pull back conduit to each side of vault.
VERO_S_SEGMENT3_CON 36.03294, -97.05143 2026-09-01 Conduit_Sealed Unassigned 6 Softscape restoration needed around vault by marker post. Conduit not sealed around fiber.
VERO_S_SEGMENT3_CON 36.02624, -97.05143 2026-09-01 Trash_Scraps Unassigned 6 Cannot have trash piles in deliverable photos. Remove trash piles and take new N,E,S,W photos.
VERO_N_SEGMENT4_CON 36.11916, -96.55882 2026-09-01 Restoration_Other Unassigned 6 softscape restoration needed around vault to bring to grade.
VERO_S_SEGMENT3_CON 36.06029, -97.05144 2026-09-01 Restoration_Other Unassigned 6 Softscape restortation needed around vault
VERO_S_SEGMENT3_CON 36.07431, -97.05155 2026-09-01 Restoration_Other Unassigned 6 softscape restoration needed around vault to bring to grade.
VERO_S_SEGMENT3_CON 36.01247, -97.05115 2026-09-01 Restoration_Other Unassigned 6 backfill around vault to fill in voids.
VERO_N_SEGMENT6_CON 36.13349, -96.23620 2026-09-01 Conduit_Length Unassigned 6 Conduits cannot be crossing, pull conduit back to each side of vault. Trim conduit to length. Ground rod not visible in interior photo.
VERO_N_SEGMENT4_CON 36.12123, -96.52508 2026-09-01 Restoration_Other Unassigned 6 softscape restoration around vault to bring to grade. Trim conduit down to length.
VERO_N_SEGMENT4_CON 36.12019, -96.54194 2026-09-01 Restoration_Other Unassigned 6 Marker post photo does not appear to belong to this vault.Softscape restoration around vault to bring to grade. Jumper wire needs to connect to tracer and ground lugs.
VERO_N_SEGMENT4_CON 36.11909, -96.58412 2026-09-01 Restoration_Other Unassigned 6 Softscape restoration needed around vault to bring to grade. Conduit and tracer wire in vault obscured by dirt/mud
VERO_N_SEGMENT4_CON 36.11910, -96.59267 2026-09-01 Restoration_Other Unassigned 6 softscape restoration around vault needed to bring to grade. Jumper wire not connected to ground wire lug.
VERO_S_SEGMENT3_CON 35.99232, -97.05102 2026-09-01 Conduit_Sealed Unassigned 6 missing sealant between conduit and fiber cable.
VERO_S_SEGMENT3_CON 36.03959, -97.05144 2026-09-01 Conduit_Sealed Unassigned 6 Conduit not sealed around fiber cable
VERO_S_SEGMENT3_CON 36.05341, -97.05139 2026-09-01 Conduit_Sealed Unassigned 6 Multiple conduit not sealed
VERO_N_SEGMENT6_CON 36.12997, -96.15272 2026-09-01 Restoration_Other Unassigned 6 Top of vault obscured by mud. Clean off vault lid and re-take restoration photos. Pull back conduit to each side of vault.
VERO_S_SEGMENT3_CON 36.00566, -97.05113 2026-09-01 Conduit_Sealed Unassigned 6 Conduit not sealed around fiber cable. Ground rod not visible.
VERO_N_SEGMENT5_CON 36.13026, -96.28400 2026-09-01 Restoration_Other Unassigned 6 Backfill material around vault to bring to grade. Remove mule tape from vault lid.
VERO_N_SEGMENT5_CON 36.13054, -96.27560 2026-09-01 Restoration_Other Unassigned 6 backfill material around vault to bring to grade. Missing interior vault photo.
VERO_S_SEGMENT3_CON 36.04656, -97.05133 2026-09-01 Trash_Scraps Unassigned 6 remove trash from inside vault
VERO_N_SEGMENT5_CON 36.12978, -96.29227 2026-09-01 Conduit_Length Unassigned 6 Pull back conduit towards both ends of vault, trim conduit if needed once pulled back. Expose all tracer wire and the ground rod.
VERO_N_SEGMENT5_CON 36.12913, -96.30916 2026-09-01 Structure_Other Unassigned 6 Missing interior vault photo. Backfill around vault to bring to grade.
VERO_N_SEGMENT6_CON 36.12192, -96.12497 2026-09-01 Structure_Grounding Unassigned 6 Ground rod needs to be placed in a corner of the vault and lower into the ground.